A drawn cup is a needle roller bearing with no inner ring: the shaft is the inner raceway, the drawn steel cup is the outer ring, and both sit in a housing that was bored before the bearing was chosen. That construction decides what the number on the box is allowed to say.
HK2010 carries four digits after the prefix, and they are two measurements printed as they are. The first pair is the shaft it runs on, 20 mm. The second pair is its width, 10 mm. Nothing is coded, nothing is multiplied by five. The outside diameter — 26 mm — is not in the string at all.
Four digits, two measurements
All 100 records in this type read the same way, and the database says so in a field: the digits are Fw and C. The field that holds an inside diameter everywhere else on this site is empty here, because there is no bore — the shaft is the raceway. What is recorded instead is a shaft size.
That is the exact opposite of the bore code on a ball bearing. There, the last two digits mean nothing until they are multiplied by five, and the digits in front of them pick a dimension series. Here every digit is a millimetre, and the prefix picks no dimension: HK and BK share their boundary dimensions and differ only in whether one end is closed.
The shaft sizes run from 3 to 60 mm in 26 steps, and the absolute step grows from 1 mm at the bottom to 10 mm at the top. What stays put is not the millimetres but the ratio between neighbours: no step is more than a third larger than the one below it — the widest is Fw 3 to 4 at 1.33 — and the tightest is Fw 17 to 18 at 1.06. A 1 mm step on a 3 mm shaft and a 10 mm step on a 60 mm shaft are the same rule seen from different sizes.
The missing dimension is a fixed allowance
The outside diameter is not in the number because it does not need to be. Split every record into wall thickness — half the difference between the outside diameter and the shaft — and the wall takes only 5 values across 26 shaft sizes: 1.75 mm at Fw 3 alone; 2 mm from Fw 4 to 12; 3 mm from Fw 12 to 22; 3.5 mm from Fw 25 to 45; 4 mm from Fw 50 to 60.
The consequence is the useful part. Between two wall steps the housing bore is the shaft plus a constant, so a shaft size read off the box also reads the housing; only at the 4 places where the wall steps do you need a table, and this is that table:
| Shaft, Fw (mm) | Outside diameter (mm) | Wall (mm) | Widths offered, C (mm) | Records |
|---|---|---|---|---|
| 3 | 6.5 | 1.75 | 6 | 2 |
| 4 | 8 | 2 | 8 | 2 |
| 5 | 9 | 2 | 9 | 2 |
| 6 | 10 | 2 | 6, 8, 9 | 4 |
| 7 | 11 | 2 | 9 | 2 |
| 8 | 12 | 2 | 8, 10 | 4 |
| 9 | 13 | 2 | 8, 10, 12 | 5 |
| 10 | 14 | 2 | 10, 12, 15 | 6 |
| 12 | 16 / 18 | 2 / 3 | 10, 12 | 4 |
| 13 | 19 | 3 | 12 | 2 |
| 14 | 20 | 3 | 12, 16 | 2 |
| 15 | 21 | 3 | 12, 16, 22 | 5 |
| 16 | 22 | 3 | 12, 16, 22 | 5 |
| 17 | 23 | 3 | 12 | 1 |
| 18 | 24 | 3 | 12, 16 | 3 |
| 20 | 26 | 3 | 10, 12, 16, 20, 30 | 6 |
| 22 | 28 | 3 | 10, 12, 16, 20 | 6 |
| 25 | 32 | 3.5 | 12, 16, 20, 26, 38 | 9 |
| 28 | 35 | 3.5 | 16, 20 | 4 |
| 30 | 37 | 3.5 | 12, 16, 20, 26, 38 | 8 |
| 32 | 39 | 3.5 | 24 | 1 |
| 35 | 42 | 3.5 | 12, 16, 20 | 5 |
| 40 | 47 | 3.5 | 12, 16, 20 | 4 |
| 45 | 52 | 3.5 | 12, 16, 20 | 4 |
| 50 | 58 | 4 | 20, 25 | 3 |
| 60 | 68 | 4 | 12 | 1 |
The wall column has 5 distinct values and the widths column is where the choice actually is. The 12 mm row is the only one with two outside diameters, and the next section is about it. One row does not land on a whole millimetre: the 3 mm shaft has a 6.5 mm outside diameter because its wall is 1.75 mm, the only fractional outside diameter in the 100 records.
One shaft, two housings
Every shaft size but one has a single outside diameter, and 96 of the 100 records sit on those unambiguous sizes. The exception is 12 mm:
| Designation | Shaft, Fw (mm) | Width, C (mm) | Outside diameter (mm) | Wall (mm) |
|---|---|---|---|---|
| BK1210 | 12 | 10 | 16 | 2 |
| HK1210 | 12 | 10 | 16 | 2 |
| BK1212 | 12 | 12 | 18 | 3 |
| HK1212 | 12 | 12 | 18 | 3 |
BK1210 puts 10 mm of width inside a 2 mm wall. BK1212 puts 12 mm of width inside 3 mm of wall. Both families offer both sizes, so these four records are the only place in the type where the box does not tell you the housing bore: it is either 16 or 18 mm.
It is not an error in either table. 12 mm is exactly where the wall ladder steps up, and at that one size both walls are offered — so the same shaft can be carried in either housing, and the wider bearing is the one that gets the thicker wall. Everywhere else the shaft decides alone.
Width is the only free number
14 widths are offered, from 6 to 38 mm, and they are not tied to the shaft: one shaft size can be had in 5 widths, and the 63 distinct sizes over 26 shaft sizes average 2.42 per shaft.
The distribution is uneven. The 12 mm width is the common one — 17 of the 26 shaft sizes offer it. At the other end, 15, 24, 25, 30 mm each serve exactly one shaft size.
Group the type by envelope — family, shaft and outside diameter — and it falls into 50 envelopes. 23 of them come in one width only; 2 of them offer 5, the widest choice anywhere in the family: Fw 20 in a 26 mm housing (10, 12, 16, 20, 30 mm) and Fw 25 in a 32 mm housing (12, 16, 20, 26, 38 mm).
The closed end costs nothing
| Family | Ends | Records | Shaft, Fw (mm) | Outside diameter (mm) | Widths offered |
|---|---|---|---|---|---|
| HK | Open ends | 62 | 3–60 | 6.5–68 | 14, 6–38 mm |
| BK | One closed end | 38 | 3–50 | 6.5–58 | 10, 6–38 mm |
HK is open at both ends and holds 62 of the 100 records; BK has one closed end. Closing an end is not a bigger part: 37 of the 38 closed records repeat an open size exactly — same shaft, same width, same outside diameter — so the only question between the two families is whether the shaft end has to be covered. BK3016 is the one size with no open twin at all.
What the closed family does give up is width: 22, 24, 25, 30 mm are made in the open family only.
What the number does not tell you
- Load rating and speed. This type is stored as boundary dimensions only. Capacity depends on the cup, the needle complement and the shaft, which are the manufacturer's numbers rather than the standard's.
- Fits. ISO 3245 fixes the boundary dimensions. How tight the housing bore and the shaft should be run is a separate table, and it is not in this database.
- The raceway is the shaft. Nothing in the number describes the surface it will run on, and that surface is half of the bearing.
- An inner ring. This type has none. If the shaft cannot serve as a raceway, the bearings index lists the families that come with one.
Start from the HK series or the BK series for the full list, or read the bore code guide to see how the other families encode the same two fields.