DIN 125 A Flat Washer — Normal Series, 140 HV
DIN version of the plain flat washer. Form A is the standard 140 HV hardness range, which is lower than the 200 HV of the ISO series.
Where it is used
DIN 125 A is the most widely used plain washer, where A denotes the standard outside diameter series (B is small OD, C is large OD). It goes under the bolt head or nut in general machine connections.
How to choose it
At 140 HV it suits class 8.8 bolts and below. With class 10.9 and above, change to a 200 HV washer such as ISO 7089 or DIN 6916, otherwise the washer may deform during tightening and leave the bolt short of its intended preload.
Dimensions13 sizes · millimetres
| Nominal size | Inside diameter d1 (mm) | Outside diameter d2 (mm) | Thickness h (mm) |
|---|---|---|---|
| M3 | 3.2 | 7 | 0.5 |
| M4 | 4.3 | 9 | 0.8 |
| M5 | 5.3 | 10 | 1 |
| M6 | 6.4 | 12 | 1.6 |
| M8 | 8.4 | 16 | 1.6 |
| M10 | 10.5 | 20 | 2 |
| M12 | 13 | 24 | 2.5 |
| M14 | 15 | 28 | 2.5 |
| M16 | 17 | 30 | 3 |
| M18 | 19 | 34 | 3 |
| M20 | 21 | 37 | 3 |
| M22 | 23 | 39 | 3 |
| M24 | 25 | 44 | 4 |
Nominal dimensions in millimetres as published in DIN 125 A. Tolerances, material requirements and marking are defined separately by the issuing body.
Available sizeslinked to individual specification pages
Fitting and interchange notes
Dimensionally interchangeable with ISO 7089. Telling the A, B and C series apart is just the ratio of outside to inside diameter: A is the standard value, B is a smaller OD for tight spaces, C a larger OD for better load spreading. If a purchase order says DIN 125 without a series, series A is the default reading.