DIN 529 A Anchor Bolt, Form A
A foundation bolt for embedding in masonry or concrete: a forged head that keys into the material, a plain shank, and a metric thread at the free end for a hexagon nut. Form A is the straight-shank variant. DIN 529 fixes the thread, the thread length b, the head columns a and c, and a series of commercial lengths from 80 to 3200 mm — and it explicitly leaves the shape of the shank to the manufacturer, so two compliant bolts can differ behind the head. Nothing on this page is calculated: the table is reproduced column for column, including the columns this site does not interpret.
Where it is used
DIN 529 A is a foundation bolt: a forged head that is cast or grouted into masonry or concrete, a plain shank, and a metric thread at the free end that takes a hexagon nut. It is not an expansion anchor and it does not grip by friction; it holds because the head is buried in the material and the nut clamps the part being fixed down. That is why the standard refuses to state a pull-out resistance: the strength of the joint comes from the concrete or the stone and from how deep the head sits, not from the bolt. Form A is the straight-shank variant, and it is the only form whose a, c and g columns are printed for every diameter the standard covers.
How to choose it
Choose the thread from the load and the nut that fits it, and the length from the thickness of the base plate plus the embedment depth the structural design calls for; the standard gives thread lengths and head columns, not embedment depths. The nut and washer are separate items and this standard dimensions neither, so the thread has to be long enough to seat both with a few turns showing. Nothing in the table varies with length — the thread length b is fixed per diameter, so a longer bolt gets a longer plain shank, not a longer thread. The standard prints no property class and no mass on the pages reproduced here; the second source we can check lists the marking for steel as 3.6 and the thread tolerance as 8g, and those two values are quoted from that source rather than from the table.
Dimensions12 sizes · millimetres
| Thread d | Pitch P (mm) | Thread length b (mm) | a (mm) | c (mm) | g (mm) |
|---|---|---|---|---|---|
| M8 | 1.25 | 20 | 24 | 45 | 30 |
| M10 | 1.5 | 25 | 30 | 55 | 38 |
| M12 | 1.75 | 30 | 36 | 65 | 45 |
| M16 | 2 | 40 | 48 | 85 | 60 |
| M20 | 2.5 | 50 | 60 | 105 | 75 |
| M24 | 3 | 60 | 75 | 125 | 90 |
| M30 | 3.5 | 75 | 95 | 155 | 115 |
| M36 | 4 | 90 | 115 | 190 | 135 |
| M42 | 4.5 | 105 | 135 | 220 | 155 |
| M48 | 5 | 120 | 155 | 250 | 180 |
| M56 | 5.5 | 140 | 180 | 290 | 210 |
| M64 | 6 | 160 | 200 | 335 | 235 |
Nominal dimensions in millimetres as published in DIN 529 A. Tolerances, material requirements and marking are defined separately by the issuing body.
Available sizeslinked to individual specification pages
Thread referencesused by the sizes above
Fitting and interchange notes
The 2010 edition supersedes the December 1986 edition and covers M8 to M72x6. Four things on this page are worth reading before the numbers. First, the standard says in as many words that the shape of the shank is left to the manufacturer, so two bolts that both conform can look different behind the head; the drawing on this page therefore stops at the point where the standard stops. Second, the columns headed a, c and g are printed as letters only. No reproduction we can check carries a legend for them; the one that comes closest glosses a as head width and c as head height, and then prints different limits from the 2010 edition for the same cells — 21 to 27 where this edition prints a nominal 24 with a maximum of 25. Rather than pick one, this page prints the letters and the numbers and draws neither. Third, the first table carries a max and c max alongside the per-form values, and those are not a single envelope over all five forms: form E exceeds c max at M24 and M42, and both cells are recorded on that form's pages. Fourth, there is no mass table at all. A mass could not honestly be calculated from these columns either, since the shank whose volume it would use is the part the standard leaves open. The commercial length series runs 80 to 3200 mm in seventeen steps; the availability chart that accompanies it marks at most seven of the thirteen diameters, so this site does not turn it into per-length pages. The largest size in the table is M72x6, which has no page here: this database's ISO 261 coarse series ends at M64, and a size without a thread record would put a gap in the size index.