ISO 4014Hexagon headExternal hexagon

ISO 4014 M8 × 30 Hexagon head

ISO 4014 M8 × 30 is a hexagon head bolt with a 30 mm nominal length, on a M8 × 1 mm metric thread. ISO version of the partial thread hexagon head bolt. The standard thread length is defined by nominal length bands, so long bolts have a proportionally longer plain shank.

Dimensioned drawing — ISO 4014 M8 × 30k 5.3L 30⌀14.38⌀8
ISO 4014 M8 × 30 — Hexagon headNominal dimensions in mm · Not to scale
Diameter8 mm
Length30 mm
Pitch1 mm
Socket size s13 mm
Head height k5.3 mm
HeadHexagon head
DriveExternal hexagon

Dimensions

Standard
ISO 4014
Type
Hexagon head bolt
Size
M8 × 30
Thread
M8 × 1
Length L
30 mm
Socket size s
13 mm
Head height k
5.3 mm
Drive
External hexagon
Head
Hexagon head

Nominal values in millimetres as published in ISO 4014. Estimated weight 11.838 g per piece in steel (11.913 g in stainless), calculated from the nominal geometry — real parts vary with tolerance and head chamfers.

DesignationM8 × 1 fine
Pitch1 mm
Nominal Ø8 mm
Pitch Ø7.35 mm
Minor Ø ext6.77 mm
Tap drillØ 7 mm

Other lengthsISO 4014 M8

All M8 specifications

Interchangeability

ISO 4014 is catalogued with DIN 931 as its equivalent designation. Dimensions are compared field by field rather than assumed identical.

Choosing and fitting this size

ISO 4014 M8 × 30 is a hexagon head in M8, 30 mm long under the head, on a 1 mm coarse pitch. Mating threads should be a matching class nut or a tapped hole of the same nominal size.

Common stock grades are 8.8, 10.9 and 12.9 in steel, plus A2-70 and A4-80 in stainless. Class 10.9 and 12.9 carry roughly 1.25 and 1.5 times the proof load of 8.8, but they also need a properly rated mating nut — a class 8 nut under a 12.9 bolt simply moves the failure into the thread. Zinc-plated 10.9 and above should be baked to avoid hydrogen embrittlement.

For a tapped hole, M8 × 1 mm takes a 7 mm tap drill, and the external thread's minor diameter is 6.77 mm — that is the section carrying the load, not the nominal M8 figure. Thread engagement of at least one times the nominal diameter is what lets the bolt fail before the thread strips.